Pax 400 - DIGITAL Panoramic and Cephalometric X Ray
Best Image Quality.LDCP (Low Dark Current Processing) Logic Circuit
Zero Noise
Ultra High Definition
Wide Range of Gray Scale
3 Positioning Beams
Voice Instruction
Clear soft tissue
To get clear soft tissue in the cephalometric image, kV and mA varies automatically during scanning. This function is automatically controlled by the capturing program. (Linear cephalometric sensor)
Contact us for more information
Rotograph EVO-D DIGITAL Panoramic and Cephalometric X Ray
Exposure time PAN 7.3 – 13.8 sec CEPH 4.5 – 15 secDose x area evaluation (DAP) StandardImage area PAN 14.6x30 , CEPH 18x22, 24x22, 29x22 cmImage Transfer: Ethernet–USB memory stickSensor Technology: CCD with high resolution Cs-I (Cesium Iodide) scintillatorCCD Pixel size: 48 μmEffective image resolution: 5.2 lp/mm Acquisition Depth : 12 bit (4096 levels)Image Size: 1536x2800 (standard PAN) - 3000 x 2305 (CEPH, max) Dicom connectivity : Print, Store, WorklistGenerator High frequency, 200kHz constant potentialHigh Voltage 60 – 86kV - Current 6– 2 mAFocal spot 0.5 IEC 336Spine compensation Automatic kV modulationWeight PAN157kg CEPH 177kg Contact us for more informationPower supply voltage 110-120 / 220-240 Vac, 50/60HzAbsorbed current 6.6 A @ 220-240 V – 15A @ 110-120 V
Pantos DG- XP : DIGITAL Panoramic and Cephalometric X Ray The Pantos DG is a digital Panoramic X-ray system of new conception, equipped with a specific detector for diagnostic imaging. The particular features of sensitivity and resolution assure consistent radiographic quality.
The use is straightforward, with automatic image acquisition displayed on a computer screen. Once displayed the image can be processed and magnified as needed to outline the m
ost important details.
CEPHALOMETRIC
The cephalometric version is available with a lateral arm to take side (Latero-Lateral) or frontal (Antero-Posterior) radiographs, of the skull, and wrist. A soft tissue filter is available with Latero-Lateral procedures.
PantOs 16 XP: Analog Panoramic and Cephalometric X Ray
Constant potential high-frequency multi-pulse X-ray generator.
Focal spot 0.5 IEC336
Technique factors: anodic voltage from 61 to 85kV, anodic current from 4 to 10mA, maximum exposure time 15sec.
Source image distance: 51cm (Pan) 165cm (Ceph)
Panoramic examinations: Adult, Child, Left-Side Dentition, Right-Side Dentition, Anterior Dentition, Temporo-Mandibular Joint (TMJ) Open/Closed Mouth, Maxillary Sinus
Cephalometric exam.:
Antero-Posterior, Latero-Lateral,Wrist
Cassette size:
Pan: 15 x 30cm Ceph: 18 x 24cm 8in. x 10in